  tel.x battery rack systems standard rack safts rack systems, together with tel.x high energy density batteries, provide a robust, lighter and reliable battery back-up solution for multiple types of telecom applications. the modular and scalable solution systems are available in two voltage ranges: 24 v and 48 v systems. available in standard 19 and 23 rack, the systems are custom fit for the overall tel.x battery range. the systems are capable to host up to 5 each 48 v battery strings per rack. this combination allows for accrued flexibility of both foot print and back-up capacity range most suitable for deployment in demanding indoor environments. with these systems, saft is able to provide a turnkey solution which significantly reduces the floor loading compared to vrla. safts rack systems are delivered pre- assembled and pre-wired. applications for wireline and wireless applications such as: ? cev, hut and shelter ? bts (base stations) ? central office ? customer premises cable harnesses and bus bar system features based on standard frame width: 19 or 23 available in 2 versions: 24 v or 48 v integrated bus bar(s) with polycarbonate cover(s) pre-wired with: direct connect or sb 50 anderson quick connect modular and scalable: up to 5 each 48 v battery strings per system (or 10 each 24 v battery strings) scalable back-up power: from 3.6 kwh up to 41 kwh all levels are liquid tight painted grey using durable epoxy powder-coat template for anchoring pattern provided system benefits compact, optimized and integrated solution significant reduction in floor loading compared to vrla (15 % to 40 %) pre-assembled and pre-wired for rapid installation flexible in voltage, capacity, dimensions and connections to answer individual customers needs increased operational reliability tel.x battery safts tel.x battery is a proven solution designed specifically for telecom applications. long life high reliability maintenance-free high energy density nebs certified
saft industrial battery group 12, rue sadi carnot 93170 bagnolet - france tel. : +33 1 49 93 19 18 fax : +33 1 49 93 19 64 www.saftbatteries.com doc. no 21808-2-0811 information in this document is subject to change without notice and becomes contractual only after written confirmation by saft. published by the communications department. photo credit: saft socit par actions simplifie au capital de 31 944 000 rcs bobigny b 383 703 873 produced in the uk by arthur associates limited battery model rack weight without batteries rack dimensions 48 v [kg] 48 v [lbs] 24 v [kg] 24 v [lbs] w [cm] w [in] d [cm] d [in] h [cm] h [in] tlx 8o 104 230 122 270 52 20.5 42 16.5 213 84 tlx 100 113 250 132 290 52 20.5 52 20.5 213 84 tlx 150 127 280 145 320 52 20.5 71 28.0 213 84 tlx 180 132 290 150 330 52 20.5 85 33.5 213 84 battery model rack weight without batteries rack dimensions 48 v [kg] 48 v [lbs] 24 v [kg] 24 v [lbs] w [cm] w [in] d [cm] d [in] h [cm] h [in] tlx 8o 109 240 127 280 62 24.5 38 15.0 213 84 tlx 100 118 260 136 300 62 24.5 42 16.5 213 84 tlx 150 132 290 150 330 62 24.5 57 22.5 213 84 tlx 180 136 300 154 340 62 24.5 68 26.7 213 84 battery model rack weight with batteries number of strings c 8 ah/ string max wh/ string floor loading [kg/m 2 ] floor loading [lbs/ft 2 ] 48 v 24 v 48 v [kg] 48 v [lbs] 24 v [kg] 24 v [lbs] tlx 8o 506 1115 524 1155 5 10 75 18000 2400 492 tlx 100 581 1280 599 1320 5 10 97 23280 2208 452 tlx 150 814 1795 832 1835 5 10 140 33600 2248 460 tlx 180 934 2060 953 2100 5 10 172 41280 2150 440 battery model rack weight with batteries number of strings c 8 ah/ string max wh/ string floor loading [kg/m 2 ] floor loading [lbs/ft 2 ] 48 v 24 v 48 v [kg] 48 v [lbs] 24 v [kg] 24 v [lbs] tlx 8o 517 1140 535 1180 5 10 75 18000 2258 462 tlx 100 624 1375 642 1415 5 10 97 23280 2460 504 tlx 150 821 1810 839 1850 5 10 140 33600 2360 483 tlx 180 930 2050 948 2090 5 10 172 41280 2246 460 notes 1. use provided information to insure proper floor loadings are respected. review building codes and respect proper engineering practices before installing the battery rack systems. always consider fully loaded battery rack systems when evaluating floor loadings. 2 anchoring mechanism and grounding straps are not provided with the rack systems. anchoring and grounding shall be done in accordance with all applicable and required company as well as local, state and federal codes. 3. saft is not liable or responsible for the improper installation of the rack systems. 19" rack system without batteries 23" rack system without batteries 19" rack system with batteries 23" rack system with batteries the floor loading data is calculated based on the full system load. the floor loading data is calculated based on the full system load. battery capacities and floor loading for the standard rack systems


▲Up To Search▲   

 
Price & Availability of TLX8O

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X